IUMI calls for improved firefighting systems on board container vessels
With the growing size of container vessels, and a recent spate of fires on board of these ships, the International Union of Marine Insurance (IUMI) is concerned that current firefighting provisions are insufficient.
Fires on board container vessels are very real threats, IUMI noted in a Sept. 19 position paper. Recent examples include fires on NNCI Arauco (9,000 TEU) in September 2016 during welding operations whilst alongside in Hamburg, Hanjin Pennsylvania (4,000 TEU) in November 2002 claiming the lives of two crew members and resulting in a constructive total loss; and MSC Flaminia (6,732TEU) in July 2012, resulting in three fatalities and also a constructive total loss.
Whilst IUMI expressly welcomes the 2014 amendment to the International Convention for the Safety of Life at Sea (SOLAS) to increase the effectiveness of firefighting, the association believes more should be done.
Helle Hammer, IUMI political forum chair said: "Recent amendments to SOLAS are a move in the right direction but they do not go far enough. The legal requirements prescribed by SOLAS were originally developed for fires on board general cargo vessels and these ships are structurally very different to a container vessel; and cargo is stored differently. We believe the mode of firefighting set out in SOLAS is not suitable for a modern containership."
IUMI supports as best practice a proposal presented by the German Insurance Association GDV that sets out an improved concept for firefighting facilities on board a containership.
Uwe-Peter Schieder, marine and loss Prevention, GDV, explained:
"We believe a new technical solution is needed to improve current firefighting practice on container vessels, particularly as these ships are continuing to grow in size.
"We suggest creating individual fire compartments below deck to prevent fire from spreading. These compartments would be fitted with fixed Co2 and water-based firefighting systems. Boundary structures would also be fitted above deck to align with the water-cooled bulkheads below and also fitted with fixed fire-fighting systems. In addition, we also recommend the installation of enhanced fire detection systems".
Already registered?
Login to your account
If you don't have a login or your access has expired, you will need to purchase a subscription to gain access to this article, including all our online content.
For more information on individual annual subscriptions for full paid access and corporate subscription options please contact us.
To request a FREE 2-week trial subscription, please signup.
NOTE - this can take up to 48hrs to be approved.
For multi-user price options, or to check if your company has an existing subscription that we can add you to for FREE, please email Elliot Field at efield@newtonmedia.co.uk or Adrian Tapping at atapping@newtonmedia.co.uk
Editor's picks
Editor's picks
More articles
Copyright © intelligentinsurer.com 2024 | Headless Content Management with Blaze